Hygienic pressure switch for absolute and gauge pressures
A3EHEDG

Pressure switch for measurement and monitoring of absolute and gauge pressure for hygienic processes

Ceraphant PTP33B [Replaces PTP35]

from Rp4,003,200.-
Need help?

Info-Hotline
+62-21-7975083

    • High reproducibility and long-term stability
    • Customized measuring ranges (without additional price)
    • Flexible process integration thanks to modular connections 

    Specs at a glance

    Product Gases, vapors, liquids and dust
    Measuring ranges From 0 to +400 mbar (0 to +6 psi) to
    0 to +40 bar (0 to +600 psi)
    Accuracy Standard: ±0.5 %;
    Platinum: ±0.3 %
    Filling oil in accordance with FDA
    Process temperature –10 to +100 °C (+14 to +212 °F),
    +135 °C (+275 °F) for one hour maximum
    Outputs 1 × PNP, 2 × PNP,
    1 × PNP + 4 to 20 mA

    Ceraphant PTP33B - Reference Accuracy : 0.5%

    Product / VersionPrice / pcs. in IDROrder code
    OutputElectrical ConnectionProcess Connection1 to 34 to 1011+
    PNP, 3-wiresM12 / ISO4400Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A4,448,000.-4,225,600.-4,003,200.- PTP33B-AA4xxxGB3CJ
    M244,551,800.-4,324,210.-4,096,620.- PTP33B-AA4xxxGBxxx
    ISO228 G14,620,300.-4,389,285.-4,158,270.- PTP33B-AA4xxxGBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent5,156,400.-4,898,580.-4,640,760.- PTP33B-AA4xxxGBxxx
    Non-hazardous areaPlug M12, IP65/67 NEMA Type 4X Encl.Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A4,690,100.-4,455,595.-4,221,090.- PTP33B-AA5MxxGB3CJ
    M244,793,900.-4,554,205.-4,314,510.- PTP33B-AA5MxxGBxxx
    ISO228 G14,862,400.-4,619,280.-4,376,160.- PTP33B-AA5MxxGBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent5,398,500.-5,128,575.-4,858,650.- PTP33B-AA5MxxGBxxx
    Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A5,220,700.-4,959,665.-4,698,630.- PTP33B-AA3MxxGB3CJ
    M245,324,500.-5,058,275.-4,792,050.- PTP33B-AA3MxxGBxxx
    Plug M12, IP65/67 NEMA Type 4X Encl.5,393,000.-5,123,350.-4,853,700.- PTP33B-AA3MxxGBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent5,929,100.-5,632,645.-5,336,190.- PTP33B-AA3MxxGBxxx

    Ceraphant PTP33B - Reference Accuracy : 0.3%

    Product / VersionPrice / pcs. in IDROrder code
    OutputElectrical ConnectionProcess Connection1 to 34 to 1011+
    PNP, 3-wiresM12 / ISO4400Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A4,929,500.-4,683,025.-4,436,550.- PTP33B-AA4xxxDB3CJ
    M245,033,300.-4,781,635.-4,529,970.- PTP33B-AA4xxxDBxxx
    ISO228 G15,101,800.-4,846,710.-4,591,620.- PTP33B-AA4xxxDBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent5,637,900.-5,356,005.-5,074,110.- PTP33B-AA4xxxDBxxx
    Non-hazardous areaPlug M12, IP65/67 NEMA Type 4X Encl.Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A5,171,600.-4,913,020.-4,654,440.- PTP33B-AA5MxxDB3CJ
    M245,275,400.-5,011,630.-4,747,860.- PTP33B-AA5MxxDBxxx
    ISO228 G15,343,900.-5,076,705.-4,809,510.- PTP33B-AA5MxxDBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent5,880,000.-5,586,000.-5,292,000.- PTP33B-AA5MxxDBxxx
    Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A5,702,200.-5,417,090.-5,131,980.- PTP33B-AA3MxxDB3CJ
    M245,806,000.-5,515,700.-5,225,400.- PTP33B-AA3MxxDBxxx
    Plug M12, IP65/67 NEMA Type 4X Encl.5,874,500.-5,580,775.-5,287,050.- PTP33B-AA3MxxDBxxx
    DIN11851 / Clamp / Tri-Clamp / Varivent6,410,600.-6,090,070.-5,769,540.- PTP33B-AA3MxxDBxxx

    Accessoires

    Product / VersionPrice / pcs. in IDROrder code
    Weld-in adapter G1, 316L Flush mount process connection. Material: 316L. Usage: PMP23, PMP51, PMP135, PTP33B/PTP35. Correct installation only with dummy.1,135,400.- 52005087
    Weld-in adapter G1, 316L, 3.1 Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Usage: PMP23, PMP51, PMP135, PTP33B/PTP35. Correct installation only with dummy.2,022,000.- 52010171
    Weld-in adapter G1, d=60, 316L Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35.561,200.- 52001051
    Weld-in adapter G1, d=60, 316L, 3.1 Flush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35.2,152,200.- 52011896
    Socket for plug 4p-125V, 4A-M12 M12 socket for plug. Self confectionery connection. Usage: plug M12.236,100.- 52006263
    Cable 4x0.34, box M12,Cu Sn/Ni,90o,L=5m M12 plug connector. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B.107,400.- 52010285
    Plug connector M12 90deg Self confectionery connection. Usage: plug M12.385,900.- 71114212

    Prices valid until 30.11.2017 in IDR per unit (not including shipping and applicable sales tax). See
    Endress+Hauser Terms and Conditions

  • Application

    The Ceraphant is a pressure transducer for the measurement of absolute and gauge pressure in gases, vapors, liquids and dust for applications with hygienic requirements. The Ceraphant can be used internationally thanks to a wide range of approvals and process connections.

    Function

    The process pressure deflects the metal process isolating diaphragm of the sensor and a fill fluid transfers the pressure to a Wheatstone bridge (semiconductor technology). The pressure-dependent change in the bridge output voltage is measured and evaluated.

    Application Example

    Hygienic pressure switch - Application example

    Pressure switch Ceraphant PTP33B with 1 × PNP switch output (b) with RMA42 / RIA45 (a) from E-direct

  • Technical data

    Output
    Output signal PNP switch output + 4 to 20 mA output (four-wire);
    PNP switch output (3-wire);
    2 × PNP switch output (4-wire)
    Signal range
    4 to 20 mA
    3.8 mA to 20.5 mA
    Voltage drop PNP ≤2 V
    Load RLmax ≤ (UB – 6.5 V) / 23 mA 1)
    Dynamic behavior Time constant (T90) 16 ms
    1) RLmax: maximum load resistance; UB: supply voltage
    Power supply
    Supply voltage 10 to 30 V DC
    Current consumption ≤60 mA
    Degree of protection - Cable: IP66/67 NEMA Type 4X/6P
    - Plug M12: IP65/67 NEMA Type 4X
    - Valve plug: IP65 NEMA Type 4X
    Influence of power
    supply
    ≤0.005 % of URL/1 V
    Residual ripple ±5 %
    Performance characteristics
    Reference accuracy

    Standard: ±0.5 %;

    Platinum: ±0.3 %

    Thermal change of
    the zero output and
    the output span

    <1 bar: <1.2 %;

    ≥1 bar: <1 %

    Long-term stability

    1 year: ±0.2 %;

    5 years: ±0.4 %

    Switch-on time ≤2 s
    Environment
    Ambient temperature –20 to +70 °C (–4 to +158 °F)
    Storage temperature –40 to +85 °C (–40 to +185 °F)
    Climate class Class 3K5
    Electromagnetic
    compatibility
    – Interference emission as per EN 61326 equipment B
    – Interference immunity as per EN 61326 appendix A (industrial sector)
    – NAMUR recommendation EMC (NE21)
    Process
    Process temperature –10 to +100 °C (+14 to +212 °F)
    Sterilization in place (SIP) at +135°C (+275 °F) for a maximum of one hour
    Materials
    Materials not in
    contact with process
    Housing: Stainless steel 316L
    Filling oil: NSF-H1 synthetic oil in accordance with FDA 21 CFR 178.3570
    Materials in
    contact with process
    Process connections: 316L
    metal process isolating diaphragm: AISI 316L
    TSE Certificate of Suitability for all device components in contact with the process
    Operability
    Operation with local
    display
    4-digit measured value display, simple and complete menu guidance, comprehensive diagnostic functions, status via LEDs
    Approvals
    3-A, EHEDG, EC1935/2004
    Pressure Equipment Directive

    Dimensions (in mm)

    Housing

    Hygienic pressure switch - Dimensions

    a) M12 plug, housing cap made of plastic

    b) Cable

    c) M16 valve plug

     

    Installation according to instruction manual.

    Process connections with flush-mounted, metal process isolating diaphragm

    a) Thread ISO 228 G 1" Metal joint

    b) Thread ISO 228 G 1" O-ring seal

    c) Thread M24×1,5

    Hygienic connections

    a) DIN 11851 DN 25

    b) DIN 11851 DN 40

    c) DIN 11851 DN 50

    d) SMS 1½"

    e) Clamp ISO 2852 DN 22

    f) Tri-Clamp ISO 2852 DN 25 – DN 38

    g) Tri-Clamp ISO 2852 DN 40 – DN 51

    h) Varivent F pipe DN25-32

    i) Varivent N pipe DN40-162

    Electrical connection

    1 × PNP switch output R1

    Hygienic pressure switch - Connecting

    a) M12 plug

    b) Valve plug

    c) Cable:

    1:   brown = L+
    2a: black = switch output 1
    2b: white = analog output 4 to 20 mA
    3:   blue = L-
    4:   green/yellow = ground
    (a): reference air hose

    2 × PNP switch outputs R1 and R2

    a) M12 plug

    b) Cable:

    1:   brown = L+
    2a: black = switch output 1
    2b: white = analog output 4 to 20 mA
    3:   blue = L-
    4:   green/yellow = ground
    (a): reference air hose

    1 × PNP switch output R1 with additional analog output 4 to 20 mA (active)

    a) M12 plug

    b) Cable:

    1: brown = L+
    2a: black = switch output 1
    2b: white = analog output 4 to 20 mA
    3: blue = L-
    4: green/yellow = ground
    (a): reference air hose

  • More documents for PTP33B
  • Previous model:

    Search:
    No results