    Specs at a glance

    Function Point level switch
    Product Liquids
    Mounting Vessels and pipes from DN50
    Product density >0.7 g/cm³ (opt. >0.5 g/cm³)
    Product temperature –40 to +100 °C/+150 °C (–40 to +212 °F /+302 °F)
    Viscosity to 10 000 mm2/s (cSt)
    Process pressure Max. 40 bar (580 psi)

    Liquiphant FTL33 with M12 connector

    Product / VersionPrice / pcs. in EUROrder code
    Sensor TypeProcess temperatureProcess Connection1 to 34 to 1011+
    Compact version 316L Ra<1.5um/59uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter197,-177,-162,- FTL33-AAxM2ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter209,-188,-171,- FTL33-AAxM2ABWSJ
    Thread M24, 316L install > accessory adapter204,-184,-167,- FTL33-AAxM2ABX2J
    DIN11851 / Tri-Clamp / ...245,-221,-201,- FTL33-AAxM2ABxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter213,-191,-174,- FTL33-AAxM3ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter224,-202,-184,- FTL33-AAxM3ABWSJ
    Thread M24, 316L install > accessory adapter220,-198,-180,- FTL33-AAxM3ABX2J
    DIN11851 / Tri-Clamp / ...261,-235,-214,- FTL33-AAxM3ABxxx
    Compact version 316L Ra<0.76um/30uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter209,-188,-171,- FTL33-AAxM2ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter221,-199,-181,- FTL33-AAxM2ACWSJ
    Thread M24, 316L install > accessory adapter216,-194,-177,- FTL33-AAxM2ACX2J
    DIN11851 / Tri-Clamp / ...257,-231,-211,- FTL33-AAxM2ACxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter224,-202,-184,- FTL33-AAxM3ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter236,-213,-194,- FTL33-AAxM3ACWSJ
    Thread M24, 316L install > accessory adapter232,-208,-190,- FTL33-AAxM3ACX2J
    DIN11851 / Tri-Clamp / ...273,-245,-224,- FTL33-AAxM3ACxxx

    Liquiphant FTL33 with valve plug

    Product / VersionPrice / pcs. in EUROrder code
    Sensor TypeProcess temperatureProcess Connection1 to 34 to 1011+
    Compact version 316L Ra<1.5um/59uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter197,-177,-162,- FTL33-AAxx2ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter209,-188,-171,- FTL33-AAxx2ABWSJ
    Thread M24, 316L install > accessory adapter204,-184,-167,- FTL33-AAxx2ABX2J
    DIN11851 / Tri-Clamp / ...245,-221,-201,- FTL33-AAxx2ABxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter213,-191,-174,- FTL33-AAxx3ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter224,-202,-184,- FTL33-AAxx3ABWSJ
    Thread M24, 316L install > accessory adapter220,-198,-180,- FTL33-AAxx3ABX2J
    DIN11851 / Tri-Clamp / ...261,-235,-214,- FTL33-AAxx3ABxxx
    Compact version 316L Ra<0.76um/30uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter209,-188,-171,- FTL33-AAxx2ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter221,-199,-181,- FTL33-AAxx2ACWSJ
    Thread M24, 316L install > accessory adapter216,-194,-177,- FTL33-AAxx2ACX2J
    DIN11851 / Tri-Clamp / ...257,-231,-211,- FTL33-AAxx2ACxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter224,-202,-184,- FTL33-AAxx3ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter236,-213,-194,- FTL33-AAxx3ACWSJ
    Thread M24, 316L install > accessory adapter232,-208,-190,- FTL33-AAxx3ACX2J
    DIN11851 / Tri-Clamp / ...273,-245,-224,- FTL33-AAxx3ACxxx

    Liquiphant FTL33 - IP69K

    Product / VersionPrice / pcs. in EUROrder code
    Sensor TypeProcess temperatureProcess Connection1 to 34 to 1011+
    Compact version 316L Ra<1.5um/59uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter221,-199,-181,- FTL33-AAxN2ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter232,-209,-191,- FTL33-AAxN2ABWSJ
    Thread M24, 316L install > accessory adapter228,-205,-187,- FTL33-AAxN2ABX2J
    DIN11851 / Tri-Clamp / ...269,-242,-221,- FTL33-AAxN2ABxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter236,-213,-194,- FTL33-AAxN3ABW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter248,-223,-203,- FTL33-AAxN3ABWSJ
    Thread M24, 316L install > accessory adapter243,-219,-200,- FTL33-AAxN3ABX2J
    DIN11851 / Tri-Clamp / ...285,-256,-233,- FTL33-AAxN3ABxxx
    Compact version 316L Ra<0.76um/30uinMax. 100°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter232,-209,-191,- FTL33-AAxN2ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter244,-220,-200,- FTL33-AAxN2ACWSJ
    Thread M24, 316L install > accessory adapter239,-216,-196,- FTL33-AAxN2ACX2J
    DIN11851 / Tri-Clamp / ...281,-253,-230,- FTL33-AAxN2ACxxx
    Max. 150°CThread ISO228 G3/4, 316L, install > accessory weld-in adapter248,-223,-203,- FTL33-AAxN3ACW5J
    Thread ISO228 G1, 316L, install > accessory weld-in adapter260,-234,-213,- FTL33-AAxN3ACWSJ
    Thread M24, 316L install > accessory adapter255,-230,-209,- FTL33-AAxN3ACX2J
    DIN11851 / Tri-Clamp / ...296,-267,-243,- FTL33-AAxN3ACxxx

    Accessories

    Product / VersionPrice / pcs. in EUROrder code
    Weld-in adapter G3/4 d=50, 316L Flush mount process connection. For vessel-mounting. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33, FMI51, FTI51, 11371. Usage: TMR35.26,52 71258355
    Weld-in adapter G3/4, d=29, 316L Flush mount process connection. For pipe-mounting. Material: 316L. Seal: silicone O-ring. FDA, EHEDG compliant. Usage: FTL20/FTL20H, FTL31/FTL33, FTW23, FTW33.26,75 71258357
    Weld-in adapter G1, d=60, 316L Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35.38,86 52001051
    Weld-in adapter G1, d=53, 316L Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTL330H/FTL330L, FTW23, FTW33, PMP135, PTP35.38,87 71258358
    Cable 4x0.34, box M12, 316L,LED,90o,L=5m M12 socket for plug + integrated LED. 5m cable PVC, 316L lock. Especially for hygiene applications. Usage: device + switch output.20,81 52018763
    Cable 4x0.34, box M12,Cu Sn/Ni,90o,L=5m M12 plug connector. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B.7,25 52010285
    Socket for plug 4p-125V, 4A-M12 M12 socket for plug. Self confectionery connection. Usage: plug M12.15,55 52006263
    Test magnet7,25 71267011

    Prices valid until 31.12.2019 in EUR per unit (not including shipping and applicable sales tax). See
    Endress+Hauser Terms and Conditions

    Is this Liquiphant level switch not the perfect match for your application?

  • Application

    The Liquiphant FTL33 is a point level switch for universal use in all liquids. It is used preferably in storage tanks, mixing vessels and pipes, where the internal and external hygiene requirements are particularly stringent. The reliable switching function works independently from product characteristics such as conductivity and dielectric constant value.

    Function

    A piezoelectric drive causes the tuning fork of the Liquiphant FTL33 to vibrate at its resonance frequency. When the tuning fork is immersed in a liquid, its intrinsic frequency changes due to the change in density of the surrounding medium. The electronics system in the point level switch monitors the resonance frequency and indicates whether the tuning fork is vibrating in air or is covered by liquid. A signal is output via the DC-PNP, AC/DC or IO-Link electrical connection.

    Application Example

    Hygienic level switch for liquids Liquiphant FTL33 - Installation

    The point level switch can be installed in any position in a vessel, pipe or tank, e.g., as overfill prevention or upper level detection (1), lower level detection (2) or dry running protection for pump (3)

  • Technical Data

    DC-PNP version
    Supply voltage 10 to 30 V DC, 3-wire
    Switching capacity 200 mA
    Current consumption <15 mA
    Electrical connection M12 connector, valve plug, cable
    AC/DC version
    Supply voltage 20 to 253 V AC/DC, 2-wire
    Switching capacity 250 mA
    Current consumption <3.8 mA (in cut-off torque <1 mA for 100 ms)
    Electrical connection Valve plug, cable
    IO-Link version
    Supply voltage 18 to 30 V DC, 4-wire
    Switching capacity 105 mA (2 × PNP), 200 mA (1 × PNP)
    Current consumption >15 mA
    Electrical connection M12 connector
    Output general
    Switching delay

    – 0.5 s when tuning fork is covered

    – 1.0 s when tuning fork is uncovered

    – IO-Link from 0.3 to 60 s

    Hysteresis max. 3 mm
    Process connections

    Thread ISO 228 G½";

    Thread ISO 228 G¾" and G1" for flushmounted installation in weld-in adapter;

    Thread ASME MNPT ½"; ¾"; 1";

    Thread M24×1,5 for flush-mounted installation in weld-in adapter or process adapter;

    DIN11851 DN25 PN40 (dairy pipe);

    DIN11851 DN32 PN40 (dairy pipe);

    DIN11851 DN40 PN40 (dairy pipe);

    Tri-Clamp ISO2852 DN25-38 (1...1½");

    Tri-Clamp ISO2852 DN40-51 (2");

    Flush-mounting in weld-in adapter RD52, tuning fork can be aligned

    Operating conditions
    Orientation As required
    Switch point

    Vertical orientation: 13 mm (0.5)

    horizontal orientation: 10.5 mm (0.4)

    (water +25 °C (+77 °F), 1 bar (14.5 psi)

    Surface roughness

    Metallic surface in contact with process:

    Ra ≤1.5 μm (59 μin), EHEDG Ra ≤0.76 μm (30 μin), EHEDG, 3-A

    Ambient temperature –40 to +70 °C (–40 to +158 °F)
    Process temperature

    –40 to +100 °C (–40 to +212 °F),

    optionally to +150 °C (to +302 °F)

    Process pressure –1 to +40 bar (–14.5 to +580 psi)
    Storage temperature –40 to +85 °C (–40 to +185 °F)
    Climate class DIN EN 60068-2-38/IEC 68-2-38: test Z/AD
    Density > 0.7 g/cm³ (optionally: > 0.5 g/cm³)
    Viscosity 1...10 000 mPa·s, dynamic viscosity
    Degree of protection

    IIP65/67 NEMA Type 4X Enclosure (M12 connector);

    IP66/68/69K NEMA Type 4X/6P Enclosure (M12 connector for metal housing cover);

    IP65 NEMA Type 4X Enclosure (valve plug);

    IP66/68 NEMA Type 4X/6P Enclosure (cable)

    Electromagnetic compatibility Electromagnetic compatibility in accordance with all relevant requirements of the EN 61326 series and NAMUR recommendation EMC (NE21). For details, refer to the EC Declaration of Conformity
    Approvals
    WHG approval

    Overfill detection system: Z-65.11-531 Leak detection system: Z-65.40-532

    Not available for IO-Link

    3-A, EHEDG  depending on selected product configuration
    EAC mark  
    RCM-Tick marking  

    Dimensions in mm (inches)

    Hygienic level switch for liquids Liquiphant FTL33 - Dimensions

    A) Thread ISO 228 G ¾" for flush-mounted installation in weld-in adapter

    B) Thread ISO 228 G 1" for flush-mounted installation in weld-in adapter

    C) DIN11851 DN25; DN32; DN40

    D)Tri-Clamp ISO2852 DN25-38; DN40-51

    E) Flush-mounting in weld-in adapter RD52

     

    * Dimension for process temperature up to 100 °C (212 °F)

    ** Dimension for process temperature up to 150 °C (302 °F)

    Installation according to instruction manual

    Electrical connection

    Electronic version 3-wire DC PNP

    Hygienic level switch for liquids Liquiphant FTL33 - Wiring the 3-wire version

    A) M12 connector

    B) Valve plug

    C) Cable

     

    Pin 1 Supply voltage +
    Pin 2 1st switch output
    Pin 3 Supply voltage -
    Pin 4 IO-Link communication or 2nd switch output (SIO mode)

    Electronic version 2-wire AC/DC

    Hygienic level switch for liquids Liquiphant FTL33 - Wiring the 2 wire version

    A) Valve plug

    B) Cable

     

    Pin 1 Supply voltage +
    Pin 2 1st switch output
    Pin 3 Supply voltage -
    Pin 4 IO-Link communication or 2nd switch output (SIO mode)

    IO-Link with one switch output

    IO-Link with one switch output FTL31

    Pin 1 Supply voltage +
    Pin 2 1st switch output
    Pin 3 Supply voltage -
    Pin 4 IO-Link communication or 2nd switch output (SIO mode)

    Terminal assignment

    Terminal assignment FTL31

    a) Minimum safety

    b) Connection for function monitoring using XOR operation

    c) Maximum safety

     

     

    Pin 1 Supply voltage +
    Pin 2 1st switch output
    Pin 3 Supply voltage -
    Pin 4 IO-Link communication or 2nd switch output (SIO mode)

  • More documents for FTL33
  • IO-Link

    Besides its general benefits, summarized below, using IO-Link point-to-point communication with our hygienic level switch
    Liquiphant FTL33 allows:

    • Adjustment to densities less than 700 g/l
    • Media diffeentiation between two media (e.g. interface detection)
    • Second switch output (parallel switching)

     

    General benefits of IO-Link

    Digital measured values:

    • Faultless transmission (e.g. EMC caused)

    • No conversion, thus a higher total accuracy

     

    More data

    • Possibility to carry more values

    • Detailed fault information

    • Additional process information

     

    Central parameters storage

    • Possibility to load set up parameters from the master into a device

    • Configuration can be duplicated from one device to the next

    • Remote sensor maintenance

  • Previous model: FTL20H

    Price / pcs. in EUR
    Liquiphant T FTL20H1 to 34 to 1011+Liquiphant FTL33
    FTL20H-0GDJ1BMax. process temperature 100oC/212oF
    197,-177,-162,- FTL33-AA1U2ABW5J
    Max. process temperature 150oC/302oF
    213,-191,-174,- FTL33-AA1U3ABW5J
    FTL20H-0GDJ2BMax. process temperature 100oC/212oF
    197,-177,-162,- FTL33-AA4U2ABW5J
    Max. process temperature 150oC/302oF
    213,-191,-174,- FTL33-AA4U3ABW5J
    FTL20H-0GDJ2DMax. process temperature 100oC/212oF
    197,-177,-162,- FTL33-AA4M2ABW5J
    Max. process temperature 150oC/302oF
    213,-191,-174,- FTL33-AA4M3ABW5J
    FTL20H-0GDJ2FMax. process temperature 100oC/212oF
    221,-199,-181,- FTL33-AA4N2ABW5J
    Max. process temperature 150oC/302oF
    236,-213,-194,- FTL33-AA4N3ABW5J
    FTL20H-0GEJ1BMax. process temperature 100oC/212oF
    209,-188,-171,- FTL33-AA1U2ABWSJ
    Max. process temperature 150oC/302oF
    224,-202,-184,- FTL33-AA1U3ABWSJ
    FTL20H-0GEJ2BMax. process temperature 100oC/212oF
    209,-188,-171,- FTL33-AA4U2ABWSJ
    Max. process temperature 150oC/302oF
    224,-202,-184,- FTL33-AA4U3ABWSJ
    FTL20H-0GEJ2DMax. process temperature 100oC/212oF
    209,-188,-171,- FTL33-AA4M2ABWSJ
    Max. process temperature 150oC/302oF
    224,-202,-184,- FTL33-AA4M3ABWSJ
    FTL20H-0GEJ2FMax. process temperature 100oC/212oF
    232,-209,-191,- FTL33-AA4N2ABWSJ
    Max. process temperature 150oC/302oF
    248,-223,-203,- FTL33-AA4N3ABWSJ
    FTL20H-0TCJ1BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA1U2AB3CJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA1U3AB3CJ
    FTL20H-0TCJ2BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4U2AB3CJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4U3AB3CJ
    FTL20H-0TCJ2DMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4M2AB3CJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4M3AB3CJ
    FTL20H-0TCJ2FMax. process temperature 100oC/212oF
    269,-242,-221,- FTL33-AA4N2AB3CJ
    Max. process temperature 150oC/302oF
    285,-256,-233,- FTL33-AA4N3AB3CJ
    FTL20H-0TDJ1BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA1U2AB3EJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA1U3AB3EJ
    FTL20H-0TDJ2BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4U2AB3EJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4U3AB3EJ
    FTL20H-0TDJ2DMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4M2AB3EJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4M3AB3EJ
    FTL20H-0TDJ2FMax. process temperature 100oC/212oF
    269,-242,-221,- FTL33-AA4N2AB3EJ
    Max. process temperature 150oC/302oF
    285,-256,-233,- FTL33-AA4N3AB3EJ
    FTL20H-0UPJ1BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA1U2AB5ZJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA1U3AB5ZJ
    FTL20H-0UPJ2BMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4U2AB5ZJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4U3AB5ZJ
    FTL20H-0UPJ2DMax. process temperature 100oC/212oF
    245,-221,-201,- FTL33-AA4M2AB5ZJ
    Max. process temperature 150oC/302oF
    261,-235,-214,- FTL33-AA4M3AB5ZJ
    FTL20H-0UPJ2FMax. process temperature 100oC/212oF
    269,-242,-221,- FTL33-AA4N2AB5ZJ
    Max. process temperature 150oC/302oF
    285,-256,-233,- FTL33-AA4N3AB5ZJ