5-digit LCD including bargraph and color alteration
-
1 or 2 channel device with mathematical functionalities
-
Wide range power supply
Specs at a glance
Inputs 1/2 universal inputs measuring current, voltage, resistance, temperature (RTD, TC)
Outputs 2 relays, 1/2 analog outputs Display LCD – 2 lines; black/white/ yellow;
alarm modus: color alteration into red;
toggle function between channels
Functionalities Linearization, mathematical calculations (+/–/avg), differential pressure package
Dimensions RIA45: 96 × 48 × 175 mm (3.78" × 1.89" × 6.89")
RIA46: 133 × 199 × 96 mm (5.24" × 7.83" × 3.78")
Panel Meter with Control Unit RIA45
Product / Version Price / pcs. in KRW Order code Approval Input; Output 1 to 3 4 to 10 11+ Non-hazardous area 1x Universal; 1x analog 372,100 353,495 334,890 RIA45-A1A1 2x Universal; 2x analog 517,000 491,150 465,300 RIA45-A1B1 1x Universal; 1x analog + 2 relay 458,600 435,670 412,740 RIA45-A1C1 2x Universal; 2x analog + 2 relay 602,200 572,090 541,980 RIA45-A1D1 ATEX / FM AIS 1x Universal; 1x analog 430,500 408,975 387,450 RIA45-xxA1 2x Universal; 2x analog 575,400 546,630 517,860 RIA45-xxB1 1x Universal; 1x analog + 2 relay 517,000 491,150 465,300 RIA45-xxC1 2x Universal; 2x analog + 2 relay 660,600 627,570 594,540 RIA45-xxD1 Field Meter with Control Unit RIA46
Product / Version Price / pcs. in KRW Order code Approval Housing Input; Output 1 to 3 4 to 10 11+ Non-hazardous area Field plastic, glass reinforced 1x Universal; 1x analog 489,400 464,930 440,460 RIA46-A1A1x 2x Universal; 2x analog 634,300 602,585 570,870 RIA46-A1B1x 1x Universal; 1x analog + 2 relay 575,900 547,105 518,310 RIA46-A1C1x 2x Universal; 2x analog + 2 relay 719,500 683,525 647,550 RIA46-A1D1x ATEX / FM AIS Field, Alu 1x Universal; 1x analog 661,800 628,710 595,620 RIA46-xxA2x 2x Universal; 2x analog 806,700 766,365 726,030 RIA46-xxB2x 1x Universal; 1x analog + 2 relay 748,300 710,885 673,470 RIA46-xxC2x 2x Universal; 2x analog + 2 relay 891,900 847,305 802,710 RIA46-xxD2x Field plastic, glass reinforced 1x Universal; 1x analog 547,800 520,410 493,020 RIA46-xxA1x 2x Universal; 2x analog 692,700 658,065 623,430 RIA46-xxB1x 1x Universal; 1x analog + 2 relay 634,300 602,585 570,870 RIA46-xxC1x 2x Universal; 2x analog + 2 relay 777,900 739,005 700,110 RIA46-xxD1x Accessory
Product / Version Price / pcs. in KRW Order code Configuration kit TXU10- for PC-programmable devices. set-up programme+interface cable for PC with USB-Port. 4 pin plug 145,900 TXU10-AC Mounting set wall+pipe (W08) 64,200 71089844 Prices valid until 31.03.2020 in EUR per unit (not including shipping and applicable sales tax). See
Endress+Hauser Terms and ConditionsPeople who bought this also watched
-
-
Application
Equipped with an extensive range of functionalities and approvals the RIA45 and RIA46 indicators suit any application in the process industries. Typical applications include displaying and monitoring process values, e.g. where overspill protection is required.
As a panel display the RIA45 is ideal for installation in control rooms, switch cabinets or laboratories while the RIA46 field indicator can be installed within hazardous areas.
Function
The indicator detects, evaluates and displays analogue process values. The integrated loop power supply provides power supply to two-wire sensors. Universal inputs allow measuring of current and voltage as well as providing a direct connection to RTDs and thermocouples. For purposes of process control, limit points can be monitored and corresponding integrated relays can be activated. The dual line LC display has been developed especially for the process industries and provides a wide range of information which is programmable. Upon pushing the quick information button the display manually or automatically switches through the various values (process, calculated or memory-values). In the event of a failure the colour of the display alternates to signal an alarm, which is easily visible from distance. The integrated application package "differential pressure" allows a quick, convenient and easy initiation in differential pressure applications.
Application Example
Example of application "differential pressure"
a) Analog In 1
b) Analog In 2
-
Technical data
Input parametersInput 1/2× universal input 0 to 20 mA, 4 to 20 mA;
Over range: up to 22 mA, 0 to 10 V, 2 to 10 V, 0 to 5 V, 1 to 5 V, ±1 V, ±10 V, ±30 V, ±100 mV, ±150 mV, 30 to 3000 Ω;
Pt 100 according to IEC751, GOST, JIS1604, Pt 500 and Pt 1000 according to IEC751;
Cu 100, Cu 50, Pt 50, Pt 46, Cu 53 according to GOST;
Ni 100, Ni 1000 according to DIN43760;
Type J, K, T, N, B, S, R according to IEC584;
Type U according to DIN43710;
Type L according to DIN43710, GOST;
Type C, D according to ASTM E998
Linearization Linearization of input and calculated values (up to 32 linearization points supported) Tolerance current 0.05 % of measurement range Output parametersAnalog output 1/2× analog output, 0 to 20 mA, 4 to 20 mA;
0 to 10 V, 2 to 10 V, 0 to 5 V;
short-circuit proof, Imax < 25 mA
Loop power supply 24 V DC (+15 % / –5 %), max. 25 mA;
short-circuit proof and overload proof;
galvanically isolated from system and outputs
Status Output Open collector to monitor device status as well as cable open circuit Relay 2 changers with function modes: min., max., gradient, alarm, out-band, in-band Limit function Max. contact burden DC 30 V / 3 A
(permanent state, without destruction of the input)Max. contact burden AC 250 V / 3 A
(permanent state, without destruction of the input)Min. contact load 500 mW (12 V/10 mA) Operating conditionsDegree of protection RIA45: Front: IP65; Back side: IP20
RIA46: IP67/NEMA 4x
Ambient temperature –20 to +60 °C (–4 to +140 °F) Storage temperature –40 to +85 °C (–22 to +185 °F) Power supplyPower supply 24 V to 230 V AC/DC Structural designFront (RIA45) 96 × 48 mm (3.78" × 1.89"), cut-out: 92 × 45 mm (3.62" × 1.77") Depth (RIA45) 151,8 mm (5.98") (w/o ex frame)
175 mm (6.89") (with mounted ex frame)
Field housing (RIA46) 133 × 199 × 96 mm (5.24" × 7.83" × 3.78") glas reinforced plastic or aluminium Electrical connection Coded, pluggable spring clip, 2,5 mm²; power supply with screw clamp Display and user InterfaceDisplay LCD 2-lines; black/white/yellow;
alarm mode: color alteration into red; toggle function;
1st line: 7 segment, 5-digit, 17 mm (0.67”) high;
2nd line: Dot-Matrix free programmable for Bargraph, TAG, unit
LED 2 × Device status; 2 × Relay status Operation using three buttons and/or via configuration software FieldCare Device Setup ApprovalsEx-Approvals ATEX II(1)GD [Ex ia] IIC;
CSA AIS, NI/I/2/ABCDEFG/T4;
FM AIS, NI/I/2/ABCDEFG/T4 TIIS [Ex ia] IIC;
NEPSI [Ex ia] IIC
Others SIL2;
WHG;
GL (German Lloyd) ship building
Software functionalitiesMin/max log function / memory, alarm logging, differential pressure application package, 2 calculation channels: sum, difference, average, linearization AccessoriesConfiguration software FieldCare Device Setup Configuration kit TXU10, USB Dimensions (in mm)
RIA45
a) Distance piece for terminals (Ex option)
Installation according to instruction manual
RIA46
Installation according to instruction manual
Electrical Connection
RIA45
a) Analog Out
RIA46
a) Connection socket for interface cable
b) Connection supply voltage
c) Connection relay 1 (optional)
d) Connection relay 2 (optional)
e) Connection analog and status output
f) Connection analog input 1
g) Connection analog input 2 (optional)
h) HART® connection sockets
i) Laser labeling of terminal assignment
-
More documents for RIA45More documents for RIA46