Specs at a glance
Product Gases, vapors, liquids and dust Output 4 to 20 mA Reference accuracy ±0.3 % Process temperature range –10 to +100 °C (+14 to +212 °F); +135 °C (+275 °F) for one hour maximum Measuring ranges From –400 to +400 mbar (–6 to +6 psi) to
–1 to +40 bar (–15 to +600 psi)Cerabar PMP23 - 4-20mA
Product / Version Price / pcs. in KRW Order code Electrical Connection Process Connection 1 to 3 4 to 10 11+ Plug M12, IP65/67 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 425,200 403,940 382,680 PMP23-AA1MxxJ3CJ M24 435,600 413,820 392,040 PMP23-AA1MxxJxxx ISO228 G1 442,400 420,280 398,160 PMP23-AA1MxxJxxx DIN11851 / Clamp / Tri-Clamp / Varivent 496,000 471,200 446,400 PMP23-AA1MxxJxxx Valve plug ISO4400 NPT1/2, IP65 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 425,200 403,940 382,680 PMP23-AA1VxxJ3CJ M24 435,600 413,820 392,040 PMP23-AA1VxxJxxx ISO228 G1 442,400 420,280 398,160 PMP23-AA1VxxJxxx DIN11851 / Clamp / Tri-Clamp / Varivent 496,000 471,200 446,400 PMP23-AA1VxxJxxx Valve plug ISO4400 M16, IP65 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 425,200 403,940 382,680 PMP23-AA1UxxJ3CJ M24 435,600 413,820 392,040 PMP23-AA1UxxJxxx ISO228 G1 442,400 420,280 398,160 PMP23-AA1UxxJxxx DIN11851 / Clamp / Tri-Clamp / Varivent 496,000 471,200 446,400 PMP23-AA1UxxJxxx Plug M12, IP66/69 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 459,700 436,715 413,730 PMP23-AA1NxxJ3CJ M24 470,100 446,595 423,090 PMP23-AA1NxxJxxx ISO228 G1 476,900 453,055 429,210 PMP23-AA1NxxJxxx DIN11851 / Clamp / Tri-Clamp / Varivent 530,500 503,975 477,450 PMP23-AA1NxxJxxx Cerabar PMP23 - 4-20mA + IO-Link
Product / Version Price / pcs. in KRW Order code Electrical Connection Process Connection 1 to 3 4 to 10 11+ Plug M12, IP65/67 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 425,200 403,940 382,680 PMP23-AA7MxxA3CJ M24 435,600 413,820 392,040 PMP23-AA7MxxAxxx ISO228 G1 442,400 420,280 398,160 PMP23-AA7MxxAxxx DIN11851 / Clamp / Tri-Clamp / Varivent 496,000 471,200 446,400 PMP23-AA7MxxAxxx Plug M12, IP66/69 NEMA Type 4X Encl. Tri-Clamp ISO2852 DN25-38 (1-1/2") DIN32676 DN25-38, EHEDG, 3A 459,700 436,715 413,730 PMP23-AA7NxxA3CJ M24 470,100 446,595 423,090 PMP23-AA7NxxAxxx ISO228 G1 476,900 453,055 429,210 PMP23-AA7NxxAxxx DIN11851 / Clamp / Tri-Clamp / Varivent 530,500 503,975 477,450 PMP23-AA7NxxAxxx Accessories
Product / Version Price / pcs. in KRW Order code Weld-in adapter G1, 316L Flush mount process connection. Material: 316L. Usage: PMP23, PMP51, PMP135, PTP33B/PTP35. Correct installation only with dummy. 108,300 52005087 Weld-in adapter G1, d=60, 316L Flush mount process connection. Material: 316L. Seal: silicone O-ring. FDA, EHEDG, 3-A compliant. Usage: FMI51/FMI52, FTI51/FTI52, FTL20/FTL20H, FTL31/FTL33, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL80/FTL81, FTL260, FTW23, FTW33, PMP23, PMP51, PMP135, PTP33B/PTP35. Usage: TM401/TM411, TMR35. 52,200 52001051 Socket for plug 4p-125V, 4A-M12 M12 socket for plug. Self confectionery connection. Usage: plug M12. 22,500 52006263 Cable 4x0.34, box M12,Cu Sn/Ni,90o,L=5m M12 plug connector. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B. 10,400 52010285 Plug connector M12 90deg Self confectionery connection. Usage: plug M12. 36,800 71114212 Cable 4x0,34, box M12, 316L, 90o, L=5m M12x1 plug. 5m cable PVC, 316L lock. Especially for hygiene applications. 53,000 52024216 Display PHX20 Plug-on display 4-20mA, 4-digit red. Plug DIN43650, protection IP65. Free scaling of indication. Voltage drop <= 5V. Usage: PMC131, PMP11/PMP21/PMP23, PMP131/135. 208,800 198,360 187,920 52022914 Prices valid until 30.09.2019 in EUR per unit (not including shipping and applicable sales tax). See
Endress+Hauser Terms and ConditionsIs this Cerabar pressure sensor not the perfect match for your application?
People who bought this also watched
-
Application
The Cerabar is a pressure sensor for the measurement of absolute and gauge pressure in gases, vapors, liquids and dust for applications with hygienic requirements. The Cerabar can be used in versatile applications thanks to a wide range of approvals and process connections.
Function
The process pressure deflects the metal process isolating diaphragm of the sensor and a fill fluid transfers the pressure to a Wheatstone bridge (semiconductor technology). The pressure-dependent change in the bridge output voltage is measured and evaluated.
-
Technical data
OutputOutput signal 4 to 20 mA (2-wire)
IO-Link 4 to 20 mA (3- or 4-wire)Signal range
4 to 20 mA3.8...20.5 mA Load 4 to 20 mA RLmax ≤ (UB – 6.5 V) / 22 mA 1) Signal on alarm
4 to 20 mAmax. alarm >21 mA;
min. alarm current adjustableDynamic behavior 4 to 20 mA: Time constant (T90) 15 ms
IO-Link: Time constant (T90) 16 ms1) RLmax: maximum load resistance; UB: supply voltage Power supplySupply voltage 10...30 V DC Current consumption 4 to 20 mA: ≤ 26 mA
IO-Link: max. ≤ 300 mADegree of protection – Cable: IP66/68 NEMA Type 4X/6P
– Plug M12 Plastic: IP65/67 NEMA Type 4X
– Plug M12 Metal: IP66/69 NEMA Type 4X
– Valve plug: IP65 NEMA Type 4XInfluence of power
supply≤0.005% of URL/1 V Residual ripple ±5 % Performance characteristicsReference accuracy ±0.3 % Thermal change of
the zerooutput and
the output span<1 bar: <1.2 %;
≥1 bar: <1 %Long-term stability 1 year: ±0.2 %;
5 years: ±0.4 %;
8 years: ±0.45 %
Switch-on time ≤2 s EnvironmentAmbient temperature
range–40 to +85 °C (–40 to +185 °F)
Devices for hazardous areas or with IO-Link: –40 to +70 °C (–40 to +158 °F)Storage temperature
range–40 to +85 °C (–40 to +185 °F) Climate class Class 4K4H Electromagnetic
compatibility– Interference emission as per EN 61326 equipment B
– Interference immunity as per EN 61326 appendix A (industrial sector)
– NAMUR recommendation EMC (NE21) (not for devices with IO-Link)ProcessProcess temperature
range–10 to +100 °C (+14 to +212 °F)
Sterilization in place (SIP) at +135°C (+275 °F) for a maximum of one hourMaterialsMaterials not in
contact with process– Housing: Stainless steel 316L
– Filling oil: NSF-H1 synthetic oil in accordance with FDA 21 CFR 178.3570Materials in contact
with process– Process connections: 316L
– metal process isolating diaphragm: AISI 316L
– TSE Certificate of Suitability for all device components in contact with the processApprovalsATEX II 1/2G Ex ia IIC T4 Ga/Gb
CSA C/US IS Cl. I Div. 1 Gr. A-D
FM IS Cl. I, Div.1 Gr. A-D T4
IEC Ex ia IIC T4 Ga/Gb
NEPSI Ex ia IIC T4
EAC Ex ia IIC T4 Ga/Gb3A, EHEDG, EC1935/2004 Pressure Equipment Directive Dimensions (in mm)
Housing
a) M12 plug, housing cap made of plastic
b) M12 plug, housing cap made of metal
c) Valve plug
d) Cable
Installation according to operation instructions
Process connections with flush-mounted, metal process isolating diaphragm
a) Thread ISO 228 G 1" Metal joint
b) Thread ISO 228 G 1" O-ring seal
c) Thread M24×1.5
Hygienic connections
a) DIN 11851 DN 25
b) DIN 11851 DN 40
c)DIN 11851 DN 50
d) SMS 1½"
e)Clamp ISO 2852 DN 22
f) Tri-Clamp ISO 2852 DN 25 – DN 38
g) Tri-Clamp ISO 2852 DN 40 – DN 51
h) Varivent F pipe DN25-32
i) Varivent N pipe DN40-162
j) Universal adapter 44 mm
Electrical connection
4...20 mA output
a) 4 to 20 mA output
b) M12 plug
c) Valve plug
d) Cable
e) Devices with IO-Link
f) M12 plug
:
1: brown = L+
2: blue = L–
3: green/yellow = ground connection
(a): reference air hose -