Hygienic compact thermometer with Pt100 or 4 to 20 mA output
A3

Hygienic temperature sensor with Pt100 or 4 to 20 mA output

Easytemp TMR35

from €73,-
Need help?

Informacja - Zamówienia
+48 71 773 00 50

    • Hygienic process connections, surface finishing Ra ≤ 0.8 µm

    • Fast response times without reduced tip

    • Compact thermometer from stainless steel

    Specs at a glance

    Temperature range –50 to +200 °C (–58 to 392 °F)
    Accuracy <0.08 %, Pt100 class A
    Immersion length (diameter)

    40 to 600 mm (⌀ 6 mm)

    (1.6 to 23.6" (⌀ 0.24"))

    Sensor response time <1.0 s (T50), <2.0 s (T90)

    Compact thermometer TMR35 w. fixed measuring range

    Product / VersionPrice / pcs. in EUROrder code
    OutputProcess ConnectionLength1 to 34 to 1011+
    4.20mAClamp > NA Connect ISO2852 DN25-38, 1-1/2, 316L, 3-A, DIN32676 DN25-40Freely selectable119,-111,-105,- TMR35-A1xxDBAX1AAA
    Microclamp 1/2" - 3/4", 316L, 3-AFreely selectable119,-111,-105,- TMR35-A1xxDMAX1AAA
    Conical metall-metall G1/2, 316LFreely selectable119,-111,-105,- TMR35-A1xxMBAX1AAA
    DIN11851 DN40 PN40, 316L, 3-AFreely selectable156,-145,-137,- TMR35-A1xxPHAX1AAA
    Varivent F DN25-32, PN40, 316L, 3-AFreely selectable156,-145,-137,- TMR35-A1xxLBAX1AAA
    G3/4, 14404/316L, 3-A,for (FTL31/33/20) Liquiphant T weld-in adapterFreely selectable156,-145,-137,- TMR35-A1xxACAX1AAA
    Spring-loaded cap-nut for mounting in thermowell G3/883 mm (3.27"); 3mm (0,12"); w/o175,-163,-154,- TMR35-A1xCR1BB1AAA
    83 mm; 3mm; metal to metal 85mm238,-221,-209,- TMR35-A1xCR1WC1AAA

    Compact thermometer TMR35 with customer specified measuring range

    Product / VersionPrice / pcs. in EUROrder code
    OutputProcess ConnectionLength1 to 34 to 1011+
    4.20mAClamp > NA Connect ISO2852 DN25-38, 1-1/2, 316L, 3-A, DIN32676 DN25-40Freely selectable119,-111,-105,- TMR35-A1XxDBAX1AAA
    Microclamp 1/2" - 3/4", 316L, 3-AFreely selectable119,-111,-105,- TMR35-A1XxDMAX1AAA
    Conical metall-metall G1/2, 316LFreely selectable119,-111,-105,- TMR35-A1XxMBAX1AAA
    DIN11851 DN40 PN40, 316L, 3-AFreely selectable156,-145,-137,- TMR35-A1XxPHAX1AAA
    Varivent F DN25-32, PN40, 316L, 3-AFreely selectable156,-145,-137,- TMR35-A1XxLBAX1AAA
    G3/4, 14404/316L, 3-A,for (FTL31/33/20) Liquiphant T weld-in adapterFreely selectable156,-145,-137,- TMR35-A1XxACAX1AAA
    Spring-loaded cap-nut for mounting in thermowell G3/883 mm (3.27"); 3mm (0,12"); w/o175,-163,-154,- TMR35-A1XCR1BB1AAA
    83 mm; 3mm; metal to metal 85mm238,-221,-209,- TMR35-A1XCR1WC1AAA

    Compact thermometer TMR35 ; Pt100 output

    Product / VersionPrice / pcs. in EUROrder code
    OutputProcess ConnectionLength1 to 34 to 1011+
    Pt100, DIN class A, 4-wireClamp > NA Connect ISO2852 DN25-38, 1-1/2, 316L, 3-A, DIN32676 DN25-40Freely selectable83,-77,-73,- TMR35-A11BDBAX1AAA
    Microclamp 1/2" - 3/4", 316L, 3-AFreely selectable83,-77,-73,- TMR35-A11BDMAX1AAA
    Conical metall-metall G1/2, 316LFreely selectable83,-77,-73,- TMR35-A11BMBAX1AAA
    DIN11851 DN40 PN40, 316L, 3-AFreely selectable119,-111,-105,- TMR35-A11BPHAX1AAA
    Varivent F DN25-32, PN40, 316L, 3-AFreely selectable119,-111,-105,- TMR35-A11BLBAX1AAA
    G3/4, 14404/316L, 3-A,for (FTL31/33/20) Liquiphant T weld-in adapterFreely selectable119,-111,-105,- TMR35-A11BACAX1AAA
    Spring-loaded cap-nut for mounting in thermowell G3/883 mm (3.27"); 3mm (0,12"); w/o139,-129,-122,- TMR35-A11CR1BB1AAA
    83 mm; 3mm; metal to metal 85mm201,-187,-177,- TMR35-A11CR1WC1AAA

    Accessories

    Product / VersionPrice / pcs. in EUROrder code
    Weld-in adapter G3/4 d=50, 316L26,52 71258355
    Configuration kit TXU10- for PC-programmable devices. set-up programme+interface cable for PC with USB-Port. 4 pin plug+ReadWin2000+adapter M12128,68 TXU10-BA
    Cable M12x1 l=5m 5m cable 4x 0.34 mm2, molded PVC angled connector, M12x1 connector screw Cu Sn/Ni, IP67.9,80 51005148

    Prices valid until 30.06.2020 in EUR per unit (not including shipping and applicable sales tax). See
    Endress+Hauser Terms and Conditions
    The transaction will be settled with a VAT invoice in PLN after conversion according to the EUR exchange sell rate at the National Bank of Poland on the day of issuing the VAT invoice.

    Is this temperature sensor not the perfect match for your application?

  • Application

    Characterized by simplicity and compact construction, the Easytemp TMR35 is available with a range of hygienic process connections. It offers good accuracy and response times and has been specifically designed for hygienic applications with 3-A certification.

    Function

    The compact thermometer consists of a Pt100 class A sensor, (optional) transducer and housing with hygienic process connection. The built-in electronics can be programmed using a PC and TXU10-BA configuration kit to convert the Pt100 input signal into a temperature linear 4 to 20 mA signal.

    Installation instructions

    Hygienic compact thermometer Easytemp TMR35 - INstallation examples

    Pipe installation

     

    a) At angle sections, against the direction of flow

    b) In smaller pipes, turned against the direction of flow

    c) Perpendicular to the direction of flow

     

    L = Insertion length

  • Technical data

    Sensor
    Sensing element 1 × Pt100
    Tolerance Class A according to IEC 751
    Process temperature –50 to +200 °C
    Material 316L
    Surface finishing Ra ≤ 0.8 µm
    Sensor diameter 6 mm (0.24")
    Sensor length 40 to 600 mm selectable (please specify)
    Response time T50 = < 1.0 s; T90 = < 2.0 s
    Max. pressure 100 bar / 1500 psi (at 100 mm / 3.94" and 20 °C / 68 °F, depending on process connection)
    Process connection
    Version

    Conical metal-to-metal connection, with G½";

    TRI-CLAMP® flange 1" 1½";

    ISO 2852 DN 25/38;

    Dairy connection DIN 11851 DN 25;

    Varivent® ⌀ 68 mm for DN 32/125

    Transmitter housing
    Degree of protection IP 66/67
    Electrical connection M12×1-plug-in connector
    Material 304
    Output characteristics
    Output signal 4 to 20 mA, 20 to 4 mA / Pt100
    Signal on alarm Sensor break; Sensor short-circuit: ≤ 3.6 mA or ≥ 21.0 mA
    Load Max. (Upower supply –10 V)/0.023 A
    Ind. current requirem. ≤3.5 mA
    Current limitation ≤23 mA
    Switch-on delay 2 s
    Power supply
    Supply voltage Ub = 10 to 35 V DC
    Residual ripple Permitted residual ripple Uss ≤ 3 V at Ub ≥ 13 V, fmax= 1 kHz
    Accuracy
    Transmitter response time 1 s
    Reference operating conditions 0 °C (32 °F) (ice bath)
    Measuring error 0.1 K (0.18 °F) or 0.08 %
    Influence of supply voltage ≤ ±0.01 %/V deviation from 24 V
    Influence of ambient temperature (temperature drift)

    Td = ±(15 ppm / K × (full scale value of measuring range + 200) + 50 ppm/K × set measuring range) × Δθ

    Δθ = deviation of ambient temperature from the reference operating condition

    Long-term stability ≤0.1 K/year or 0.05 %/year
    Influence of load ≤ ±0.02 % / 100 Ω
    Operating conditions
    Ambient temperature -40 to +85 °C (-40 to 185 °F)
    Storage temperature -40 to +85 °C (-40 to 185 °F)
    Climate class As per EN 60 654-1, Class C
    Shock resistance 4 g/2 to 150 Hz as per IEC 60068-2-6
    EMC According to IEC 61326 Series and NAMUR NE21
    Approvals

    3A

     

    Dimensions (in mm)

    Hygienic compact thermometer Easytemp TMR35 - Dimensions

    a) TRI-CLAMP®

    b) MicroClamp TriClamp

    c) Dairy connection

    d) G½"

    e) Varivent®

    f) with cap-nut G3/8"

     

     

    * Version with extension neck add 35 mm (1.38")

    L = selectable length from 40 to 600 mm (1.6" to 23.6")

     

    Installation according to operation instructions

    Thermowells

    Hygienic compact thermometer Easytemp TMR35 - Thermowells

    a) Thermowell G ½"

    b) Thermowell corner piece DN15

    c) Thermowell T-piece (straight) DN10

    Electrical connection

    4 to 20 mA

    Hygienic compact thermometer Easytemp TMR35 - Wiring 1

    1 × Pt100

    Hygienic compact thermometer Easytemp TMR35 - Wiring 2

    a) red

    b) white

    Measuring range

    Code

    Measuring range

    A

    0...+100 °C

    B

    0...+150 °C

    C

    –50...+100 °C

    D

    –50...+150 °C

    E

    –50...+200 °C with extension neck

    F

    0...+200 °C with extension neck

    X

    Freely selectable (Temperature range: –50...+150 °C, please specify)
  • More documents for TMR35