Specs at a glance
Measuring range –50 to +200 °C (–58 to +392 °F) Pressure range up to 50 bar (725 psi) Response time Pt100: 5 s (T63), 11 s (T90); iTHERM TipSens: 1.0 s (T63), 2.0 s (T90) Predecessors TMR31 and TMR35 iTHERM CompactLine TM311 - Threaded connection - PT100
Product / Version Price / pcs. in EUR Order code Output Design; Diameter Insert Process Connection 1 to 3 4 to 10 11+ Pt100, 4-wire class A (IEC 60751) W/o thermowell, direct contact; 6mm G1/2 male thread ISO228, 316L / G1/4 male thread ISO228, 316L 95.70 86.13 78.47 TM311-AAA0BxxBBX1A2 With thermowell; 3mm Compression fitting G1/2 male thread, TK40-BADA3C, 316L 244.38 219.94 200.39 TM311-AAA2BG7BBX1B2 Installation in existing thermowell; 3mm Not needed 138.18 124.36 113.31 TM311-AAA1AA0ABX1B2 iTHERM CompactLine TM311 - Threaded connection - 4..20mA
Product / Version Price / pcs. in EUR Order code Output Design; Diameter Insert Process Connection 1 to 3 4 to 10 11+ IO Link/4-20mA, variable measuring range, as specified W/o thermowell, direct contact; 6mm G1/2 male thread ISO228, 316L / G1/4 male thread ISO228, 316L 135.53 121.98 111.13 TM311-AAB0BxxBBX1A2 With thermowell; 3mm Compression fitting G1/2 male thread, TK40-BADA3C, 316L 284.21 255.79 233.05 TM311-AAB2BG7BBX1B2 Installation in existing thermowell; 3mm Not needed 178.01 160.21 145.97 TM311-AAB1AA0ABX1B2 iTHERM CompactLine TM311 - Hygienic connection - PT100
Product / Version Price / pcs. in EUR Order code Design; Diameter Insert Process Connection 1 to 3 4 to 10 11+ W/o thermowell, direct contact; 6mm Microclamp, DN18 (0.75") / Tri-clamp, DN18 (0.75") / Clamp ISO2852, DN12 - 21.3 / Clamp > NA Connect ISO2852, DN25 - 38 (1-1.5") / Clamp > NA Connect ISO2852, DN40 - 51 (2") 85.08 76.57 69.77 TM311-AAA0BxxBBX1A2 Weld-in adapter cylindrical, D 30x40mm / Weld-in adapter cylindrical, D 12x40mm / Weld-in adapter spherical-cylindrical, D 30x40mm / Weld-in adapter spherical, D 25mm 95.70 86.13 78.47 TM311-AAA0BxxBBX1A2 Dairy fitting DIN11851, DN25 / Dairy fitting DIN11851, DN32 / Dairy fitting DIN11851, DN40 / Dairy fitting DIN11851, DN50 122.25 110.03 100.25 TM311-AAA0BxxBBX1A2 D45 process adapter / APV Inline, DN50 122.25 110.03 100.25 TM311-AAA0BxxBBX1A2 Varivent type B, D 31mm / Varivent type F, D 50mm / Varivent type N, D 68mm 122.25 110.03 100.25 TM311-AAA0BxxBBX1A2 90.39 81.35 74.12 TM311-AAA0BH2BBX1A2 With thermowell; 3mm Microclamp, DN18 (0.75") / Tri-clamp, DN18 (0.75") / Clamp ISO2852, DN12 - 21.3 / Clamp > NA Connect ISO2852, DN25 - 38 (1-1.5") / Clamp > NA Connect ISO2852, DN40 - 51 (2") 132.87 119.58 108.95 TM311-AAA2BxxBBX1A2 Weld-in adapter cylindrical, D 30x40mm / Weld-in adapter cylindrical, D 12x40mm / Weld-in adapter spherical-cylindrical, D 30x40mm / Weld-in adapter spherical, D 25mm 143.49 129.14 117.66 TM311-AAA2BxxBBX1A2 Dairy fitting DIN11851, DN25 / Dairy fitting DIN11851, DN32 / Dairy fitting DIN11851, DN40 170.04 153.04 139.43 TM311-AAA2BxxBBX1A2 217.65 195.89 178.47 TM311-AAA2BA1BBX1A2+CA Tee thermowell, DIN11865-A, DN20 PN25 / Tee thermowell, DIN11865-A, DN32 PN25 / Tee thermowell, DIN11865-A, DN10 PN25 / Tee thermowell, DIN11865-A, DN15 PN25 / Tee thermowell, DIN11865-A, DN25 PN25 363.68 327.31 298.22 TM311-AAA2BxxBBX1A2+CA Elbow thermowell, DIN11865-A, DN20 PN25 / Elbow thermowell, DIN11865-A, DN32 PN25 / Elbow thermowell, DIN11865-A, DN10 PN25 / Elbow thermowell, DIN11865-A, DN15 PN25 / Elbow thermowell, DIN11865-A, DN25 PN25 398.19 358.37 326.52 TM311-AAA2BxxBBX1A2+CA iTHERM CompactLine TM311 - Hygienic connection - 4..20m A
Product / Version Price / pcs. in EUR Order code Design; Diameter Insert Process Connection 1 to 3 4 to 10 11+ W/o thermowell, direct contact; 6mm Microclamp, DN18 (0.75") / Tri-clamp, DN18 (0.75") / Clamp ISO2852, DN12 - 21.3 / Clamp > NA Connect ISO2852, DN25 - 38 (1-1.5") / Clamp > NA Connect ISO2852, DN40 - 51 (2") 124.91 112.42 102.43 TM311-AAB0BxxBBX1A2 Weld-in adapter cylindrical, D 30x40mm / Weld-in adapter cylindrical, D 12x40mm / Weld-in adapter spherical-cylindrical, D 30x40mm / Weld-in adapter spherical, D 25mm 135.53 121.98 111.13 TM311-AAB0BxxBBX1A2 Dairy fitting DIN11851, DN25 / Dairy fitting DIN11851, DN32 / Dairy fitting DIN11851, DN40 162.08 145.87 132.91 TM311-AAB0BxxBBX1A2 D45 process adapter / APV Inline, DN50 162.08 145.87 132.91 TM311-AAB0BxxBBX1A2 Varivent type B, D 31mm / Varivent type F, D 50mm / Varivent type N, D 68mm 162.08 145.87 132.91 TM311-AAB0BxxBBX1A2 130.22 117.20 106.78 TM311-AAB0BH2BBX1A2 With thermowell; 3mm Microclamp, DN18 (0.75") / Tri-clamp, DN18 (0.75") / Clamp ISO2852, DN12 - 21.3 / Clamp > NA Connect ISO2852, DN25 - 38 (1-1.5") / Clamp > NA Connect ISO2852, DN40 - 51 (2") 172.70 155.43 141.61 TM311-AAB2BxxBBX1A2 Weld-in adapter cylindrical, D 30x40mm / Weld-in adapter cylindrical, D 12x40mm / Weld-in adapter spherical-cylindrical, D 30x40mm / Weld-in adapter spherical, D 25mm 183.32 164.99 150.32 TM311-AAB2BxxBBX1A2 Dairy fitting DIN11851, DN25 / Dairy fitting DIN11851, DN32 / Dairy fitting DIN11851, DN40 209.87 188.88 172.09 TM311-AAB2BxxBBX1A2 257.48 231.73 211.13 TM311-AAB2BA1BBX1A2+CA Tee thermowell, DIN11865-A, DN20 PN25 / Tee thermowell, DIN11865-A, DN32 PN25 / Tee thermowell, DIN11865-A, DN10 PN25 / Tee thermowell, DIN11865-A, DN15 PN25 / Tee thermowell, DIN11865-A, DN25 PN25 403.51 363.16 330.88 TM311-AAB2BxxBBX1A2+CA Elbow thermowell, DIN11865-A, DN20 PN25 / Elbow thermowell, DIN11865-A, DN32 PN25 / Elbow thermowell, DIN11865-A, DN10 PN25 / Elbow thermowell, DIN11865-A, DN15 PN25 / Elbow thermowell, DIN11865-A, DN25 PN25 438.02 394.22 359.18 TM311-AAB2BxxBBX1A2+CA Prices valid until 31.03.2020 in EUR per unit (not including shipping and applicable sales tax). See
Endress+Hauser Terms and ConditionsPeople who bought this also watched
-
-
Application
iTHERM CompactLine TM311 is developed for universal use in hygienic and aseptic applications in the food & beverages and pharmaceutical industries, and for optimum standardization for machine and skid builders.
Function
The compact thermometer measures the process temperature with a Pt100 sensor element (class A, 4-wire). An optional built-in transmitter converts the Pt100 input signal. The device with integrated electronics automatically detects the type of communication (IO-Link or 4 to 20 mA).
Application example
The immersion length of the compact thermometer can considerably influence the accuracy. If the immersion length is too short, measurement errors can occur as a result of heat conduction via the process connection and the vessel wall.
If installing in a pipe, the immersion length should ideally correspond to half of the pipe diameter.Installation possibilities: pipes, tanks or other plant components.
-
Technical data
InputMeasuring range – Pt100 (TF) basic: –50 to +150 °C (–58 to +302 °F)
– TipSens: –50 to +200 °C (–58 to +392 °F)OutputOutput signal – Sensor: Pt100, 4-wire connection, class A
– Analog: 4 to 20 mA; variable measuring range
– Digital: C/Q (IO-Link or switch output)Switching capacity – 1 × PNP switch output
– Switch state ON Ia ≤ 200 mA; switch state OFF Ia ≤ 10 μA
– Voltage drop PNP ≤ 2 VSwitch output Response time ≤ 100 ms Damping Configurable sensor input damping 0 to 120 s Switch-on delay 2 s Power supplySupply voltage IO-Link/4 to 20 mA: Ub = 10 to 30 VDC, protected against reverse polarity Performance characteristicsReference operating conditions – Adjustment temperature (ice bath): 0 °C (32 °F) for sensor
– Ambient temperature range: 25 °C ± 3 °C(77 °F ± 5 °F) for electronics
– Supply voltage: 24 VDC ± 10 %
– Relative humidity: < 95 %Maximum measured error – Thermometer without electronics: 0.55 °C (0.99 °F)
– Thermometer with electronics: ≤0.48 °C (0.86 °F)
– Thermometer with electronics and sensor-transmitter-matching/increased accuracy: ≤0.14 °C (0.25 °F)Response time T63
and T90– 6 mm direct contact, straight tip Pt100 (TF) basic: T63 5 s; T90 11 s
– 6 mm direct contact, straight tip iTHERM TipSens: T63 1 s; T90 2 s
– 6 mm thermowell, straight tip (4.3 × 20 mm) iTHERM TipSens: T63 1 s; T90 3 sElectronics response time Max. 1 s Sensor current ≤ 1 mA EnvironmentAmbient temperature range –40 to +85 °C (–40 to +185 °F) Storage temperature –40 to +85 °C (–40 to +185 °F) Climate class As per IEC/EN 60654-1, Class Dx Degree of protection As per IEC/EN 60529 IP69 Shock and vibration resistance The thermometer meets the requirements of IEC 60751, which specifies shock and vibration resistance of 3 g in the 10 to 500 Hz range Electrical safety – Protection class III
– Overvoltage category II
– Pollution level 2Dimensions in mm (in)
Without thermowell
U – Variable immersion length, depending on the configuration
A – Thermometer with spring-loaded cap-nut, G3/8" thread 3 mm for existing thermowell
B – Thermometer with spring-loaded NPT½" male thread 3 mm for existing thermowell
C – Thermometer without process connection for compression fitting, with extension neck
D – Thermometer with G½" male thread
E – Thermometer with G¼" male thread
F– Thermometer with M14 male thread
G – Thermometer with M18 male thread
H – Thermometer with NPT½" male thread
I – Thermometer with Microclamp, DN18 (0.75")
J – Thermometer with Tri-Clamp, DN18 (0.75")
Pay attention to the following equations when calculating the immersion length U for an existing thermowell:
Version 1 (G3/8" cap-nut): U = U(thermowell) + T(thermowell) + 3 mm - B(thermowell)
Version 2 (NPT½" male thread): U = U(thermowell) + T(thermowell) + 11 mm - B(thermowell)
K – Thermometer with ISO2852 clamp for DN12 to 21.3, DN25 to 38, DN40 to 51
L – Thermometer with milk pipe connection DIN11851 for DN25/DN32/DN40/DN50
M – Thermometer with metal sealing system G½"
N – Thermometer with G¾" male thread ISO228 for FTL31/33/20/50 Liquiphant adapter
O – Thermometer with D45 process adapter
P – Thermometer with APV in-line, DN50
Q – Thermometer with Varivent type B, D 31 mm
R – Thermometer with Varivent type F, D 50 mm and Varivent Typ N, D 68 mm
S – Thermometer with SMS 1147, DN25/DN38/DN51With compression fitting
Thermowell version as T-piece or elbow piece
V – Thermometer with TK40 compression fitting, cylindrical, Elastosil ferrule, ⌀ 25 mm, for weld-in
W – Thermometer with thermowell as T-piece
X – Thermometer with thermowell as elbow pieceWith thermowell diameter 6 mm (¹⁄₄ in)
A1 – Thermometer with weld-in adapter, cylindrical, D 12 × 40 mm
B1 – Thermometer with weld-in adapter, cylindrical, D 30 × 40 mm
C1 – Thermometer with weld-in adapter, spherical-cylindrical, D 30 × 40 mm
D1 – Thermometer with weld-in adapter, spherical, D 25 mm
E1 – Thermometer with milk pipe connection DIN11851, DN25/DN32/DN40
F1 – Thermometer with Microclamp, DN18 (0.75")Electrical connection
G1 - IO-Link operating mode
1 – Pin 1 - power supply 15 to 30 VDC
2 – Pin 2 - not used
3 – Pin 3 - power supply 0 VDC
4 – Pin 4 - C/Q (IO-Link or switch output)H1 - 4 to 20 mA operating mode
1 – Pin 1 - power supply 10 to 30 VDC
2 – Pin 2 - power supply 0 VDC
3 – Pin 3 - not used
4 – Pin 4 - not usedI1 - Without electronics
Pt100, 4-wire connection
-
More documents for TM311
-
IO-Link
Besides its general benefits, summarized below, using IO-Link point-to-point communication with our temperature sensor TM311 allows:
- Commissioning via software
- Storage of the configuration
- Use as simple temperature switch (1 Output)
General benefits of IO-Link
Digital measured values:
- Faultless transmission (e.g. EMC caused)
- No conversion, thus a higher total accuracy
More data
- Possibility to carry more values
- Detailed fault information
- Additional process information
Central parameters storage
- Possibility to load set up parameters from the master into a device
- Configuration can be duplicated from one device to the next
- Remote sensor maintenance