Vibronic limit switches for bulk solids

Vibronic rod limit switches for bulk solids

Soliphant T FTM20 / FTM21

from €250.65
Need help?

Bilgi Hattı
+90 212 275 1355

    • No calibration: easy commissioning

    • Insensitive to build-up

    • Sensor material 316L

    Specs at a glance

    Function Level switch
    Product Non-fluidized bulk solids
    Probe length

    Compact design: 225 mm (8.86");

    with extension rod: 500, 1000 or 1500 mm (19.67, 39.37 or 59.06")

    Product density ≥200 g/l
    Process pressure –1 to +25 bar (–14.5 to +363 psi)
    Product temperature –40 to +150 °C (–40 to +302 °F)

    Soliphant FTM20 : short rod version

    Product / VersionPrice / pcs. in EUROrder code
    ApprovalElectronics; OutputHousing; Cable Entry1 to 34 to 1011+
    Non-hazardous areaFEM22; 3-wire PNP 10-45VDCF16 Polyester IP66/67 NEMA4X; M20 gland284.83264.89250.65 FTM20-Ax22A
    F18 Alu IP66/67 NEMA4X; M20 gland307.64286.11270.72 FTM20-Ax25A
    FEM24; relay DPDT, 19-253VAC/55VDCF16 Polyester IP66/67 NEMA4X; M20 gland304.25282.95267.74 FTM20-Ax42A
    F18 Alu IP66/67 NEMA4X; M20 gland327.06304.17287.81 FTM20-Ax45A
    ATEX II 1/3D Ex t IIIC T 170oC Da/DcFEM22; 3-wire PNP 10-45VDCF18 Alu IP66/67 NEMA4X; M20 gland389.24361.99342.53 FTM20-4x25A
    FEM24; relay DPDT, 19-253VAC/55VDCF18 Alu IP66/67 NEMA4X; M20 gland408.66380.05359.62 FTM20-4x45A

    Soliphant FTM21 with L=500mm

    Product / VersionPrice / pcs. in EUROrder code
    ApprovalElectronics; OutputHousing; Cable Entry1 to 34 to 1011+
    Non-hazardous areaFEM22; 3-wire PNP 10-45VDCF16 Polyester IP66/67 NEMA4X; M20 gland358.82333.70315.76 FTM21-Ax222A
    F18 Alu IP66/67 NEMA4X; M20 gland381.63354.92335.83 FTM21-Ax225A
    FEM24; relay DPDT, 19-253VAC/55VDCF16 Polyester IP66/67 NEMA4X; M20 gland378.24351.76332.85 FTM21-Ax242A
    F18 Alu IP66/67 NEMA4X; M20 gland401.05372.98352.92 FTM21-Ax245A
    ATEX II 1/3D Ex t IIIC T 170oC Da/DcFEM22; 3-wire PNP 10-45VDCF18 Alu IP66/67 NEMA4X; M20 gland463.23430.80407.64 FTM21-4x225A
    FEM24; relay DPDT, 19-253VAC/55VDCF18 Alu IP66/67 NEMA4X; M20 gland482.65448.86424.73 FTM21-4x245A

    Soliphant FTM21 with L=1000mm

    Product / VersionPrice / pcs. in EUROrder code
    ApprovalElectronics; OutputHousing; Cable Entry1 to 34 to 1011+
    Non-hazardous areaFEM22; 3-wire PNP 10-45VDCF16 Polyester IP66/67 NEMA4X; M20 gland441.73410.81388.72 FTM21-Ax322A
    F18 Alu IP66/67 NEMA4X; M20 gland464.54432.02408.80 FTM21-Ax325A
    FEM24; relay DPDT, 19-253VAC/55VDCF16 Polyester IP66/67 NEMA4X; M20 gland461.15428.87405.81 FTM21-Ax342A
    F18 Alu IP66/67 NEMA4X; M20 gland483.96450.08425.88 FTM21-Ax345A
    ATEX II 1/3D Ex t IIIC T 170oC Da/DcFEM22; 3-wire PNP 10-45VDCF18 Alu IP66/67 NEMA4X; M20 gland546.14507.91480.60 FTM21-4x325A
    FEM24; relay DPDT, 19-253VAC/55VDCF18 Alu IP66/67 NEMA4X; M20 gland565.56525.97497.69 FTM21-4x345A

    Soliphant FTM21 with L=1500mm

    Product / VersionPrice / pcs. in EUROrder code
    ApprovalElectronics; OutputHousing; Cable Entry1 to 34 to 1011+
    Non-hazardous areaFEM22; 3-wire PNP 10-45VDCF16 Polyester IP66/67 NEMA4X; M20 gland525.54488.75462.48 FTM21-Ax422A
    F18 Alu IP66/67 NEMA4X; M20 gland548.35509.97482.55 FTM21-Ax425A
    FEM24; relay DPDT, 19-253VAC/55VDCF16 Polyester IP66/67 NEMA4X; M20 gland544.96506.81479.56 FTM21-Ax442A
    F18 Alu IP66/67 NEMA4X; M20 gland567.77528.03499.64 FTM21-Ax445A
    ATEX II 1/3D Ex t IIIC T 170oC Da/DcFEM22; 3-wire PNP 10-45VDCF18 Alu IP66/67 NEMA4X; M20 gland629.95585.85554.36 FTM21-4x425A
    FEM24; relay DPDT, 19-253VAC/55VDCF18 Alu IP66/67 NEMA4X; M20 gland649.37603.91571.45 FTM21-4x445A

    Accessories

    Product / VersionPrice / pcs. in EUROrder code
    Sliding sleeve R1-1/2 SS, FTM21, press. Switch point adjustment. Material: 316L. Pressurized. Usage: FTM21.215.22 52023312
    Sliding sleeve R1-1/2 SS, FTM21 Switch point adjustment. Material: 316L. Pressureless. Usage: FTM21.128.12 52023313

    Prices valid until 31.08.2017 in EUR per unit (not including shipping and applicable sales tax). See
    Endress+Hauser Terms and Conditions

  • Application

    The Soliphant T is a robust point level switch for silos containing fine or coarse-grained, non-fluidized bulk solids. Soliphant T works independently from dielectric constant value and conductivity. The various designs that are available means the device has a wide range of applications. Soliphant T is available in 4 lengths and the probe length of extended versions can be easily adjusted using a sliding sleeve (see accessories).  

    Function

    A piezoelectric drive excites the vibrating rod of Soliphant T FTM20/FTM21 to its resonance frequency. If medium covers the vibrating rod, the rods vibrating amplitude changes (the vibration is damped). Soliphants electronics compare the actual amplitude with a target value and indicates whether the vibrating rod is vibrating freely or whether it is covered by medium. The process connection is de-coupled from the rods vibration movements and thus is insensitive to vibrations and noise.

    Control systems, switching units, signalling systems (e.g. lamps, horns, PCS, PLC, etc.) can be directly connected. Minimum/maximum quiescent current safety can be switched at electronic insert.

     

    Application example

    Vibronic level switches for bulk solids - Application example

    The entire measuring system consists of:

    • Soliphant T FTM20 or FTM21 with FEM22 or FEM24 electronic insert
    • A supply point and
    • The connected control systems, switching units, signalling systems (e.g. lamps, horns, PCS, PLC, etc.)
    .
    a) Zone 20
    b) Zone 22
  • Technical data

    Output parameters
    Fail-safe mode Minimum/maximum quiescent current
    Drop-out signal Output locked
    Switching delay 0.5 s when the sensor is covered, 1 s when the sensor is exposed
    Accuracy
    Reference operating conditions Temperature 23 °C (73 °F); medium ABS granules; grain size 2 to 3.5 mm (0.08 to 0.14"); atmospheric pressure; installation: vertical from above or below; horizontal from the side
    Measuring frequency 700 to 800 Hz
    Measured error max. ≤5 mm (0.2")
    Repeatability <1 mm (0.04")
    Start-up setting time 2 s
    Ambient conditions
    Ambient temperature –40 to +70 °C (–40 to +158 °F)
    Storage temperature –40 to +85 °C (–40 to +185 °F)
    Climate class Tropicalized as per DIN IEC 68 part 2-38
    Ingress protection IP66/IP67
    Electrical safety IEC 61010, CSA 1010.1-92, FM3600
    Vibration resistance DIN 60068-2-27/IEC 68-2-27; shock 30 g; vibration 0.01 g²/Hz
    EMC Interference emission to EN 61326, Electrical Equipment Class B; Interference immunity to EN 61326 Annex A (Industrial)
    Process conditions
    Measuring range ≥200 g/l within the length of the measuring rod
    Density ≥200 g/l, not fluidized
    Process pressure –1 to +25 bar (–14.5 to +363 psi)
    Process temperature –40 to +150 °C (–40 to +302 °F)
    Materials of construction
    Sensor 316L
    Process connection R1; 1½ (316L)
    Housing F16 (plastics) / F18 (aluminium)
    Electrical connection
    Cable specification Use a usual commercial two-, three- or four-wire cable (25 Ω)
    Cable entries M20×1.5
    Approvals
    Ex approval ATEX II 1/3 D  

    Dimensions (in mm)

    FTM20 (compact design, polyester housing)

    Vibronic level switches for bulk solids - Dimensions of the short version

    Installation according to instruction manual

    FTM21 vibrating rod with extension pipe (aluminium housing)

    Vibronic level switches for bulk solids - Dimensions of the long version

    L = 500 / 1000 / 1500 mm (20"/40"/60")

     

    Installation according to instruction manual.

    Sliding sleeve: R1½" pressurized

    Suitable for multiple switch-point configurations

     

     

    Sliding sleeve: R1½" non-pressurized

    Only suitable for one-time switch-point configuration!

    Electrical connection

    Electronic insert FEM22 (DC PNP)
    Power supply 10 to 45 V DC
    Current consumption max. 18 mA
    Output Positive signal at electronics switch output (PNP); max. 350 mA, short-circuit protection); residual voltage < 3 V
    Preferred in conjunction with programmable logic controllers (PLC), DI modules as per EN 61131-2.
    Vibronic level switches for bulk solids - Connecting the DC PNP version

    a) e. g. Relay PLC

    Electronic insert FEM24 (AC/DC with relay output)
    Power supply

    19 to 253 V AC 50/60 Hz

    19 to 55 V DC

    Power consumption approx. 1.3 VA
    Output

    Loads switched via 2 floating changeover contacts.

    I~ max. 6 A,

    U~ max. 253 V;

    P~ max. 1500 VA, cos φ = 1

    P~ max. 750 VA, cos φ > 0.7

    I– max. 6 A to 30 V

    I– max. 0.2 A to 125 V

    Both relay contacts switch simultaneously.

    Please note the different voltage ranges for direct and alternating current.q qs

    Vibronic level switches for bulk solids - Connecting the version with relay output

    * When jumpered, the relay output works with NPN logic.

    a) PE (Ground)

  • More documents for FTM20