Hygienic compact thermometer with Pt100 or 4 to 20 mA output

Hygienic temperature sensor with Pt100 or 4 to 20 mA output

Easytemp TMR35

from $125.-
Payment on invoice or with
  • Maestro
  • MasterCard
  • Visa
Need help?

Info-Hotline
888-343-4732

    • Hygienic process connections, surface finishing Ra ≤ 0.8 µm (32 μin)

    • Fast response times without reduced tip

    • Compact thermometer from stainless steel

    Specs at a glance

    Temperature range –50 to +200 °C (–58 to 392 °F)
    Accuracy <0.08 %, Pt100 class A
    Immersion length (diameter)

    40 to 600 mm (⌀ 6 mm)

    (1.6 to 23.6" (⌀ 0.24"))

    Sensor response time <1.0 s (T50), <2.0 s (T90)

    Easytemp TMR35, compact thermometer

    Product / VersionPrice / pcs. in USDOrder code
    Process ConnectionOutput; Measuring RangeInsertion Length L; Diam. D; Thermowell1 to 34 to 1011+
    Clamp4-20mA; 0...100oC (32...212oF)30 mm (1.18"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1AAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1AAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1AAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1AAxxAX1AAA
    4-20mA; 0...150oC (32...302oF)30 mm (1.18"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1BAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1BAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1BAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1BAxxAX1AAA
    4-20mA, see additional spec.30 mm (1.18"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1XAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1XAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1XAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1XAxxAX1AAA
    4-20mA; 0...200oC (32...392oF)30 mm (1.18"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1FBxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1FBxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1FBxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A1FBxxAX1AAA
    Pt100, DIN class A, 4-wire..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o142.-132.-125.- TMR35-A11AxxAX1AAA
    Varivent4-20mA; 0...100oC (32...212oF)30 mm (1.18"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1AAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1AAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1AAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1AAxxAX1AAA
    4-20mA; 0...150oC (32...302oF)30 mm (1.18"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1BAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1BAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1BAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1BAxxAX1AAA
    4-20mA, see additional spec.30 mm (1.18"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1XAxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1XAxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1XAxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1XAxxAX1AAA
    4-20mA; 0...200oC (32...392oF)30 mm (1.18"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1FBxxAA1AAA
    50 mm (1.97"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1FBxxAB1AAA
    100 mm (3.94"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1FBxxAC1AAA
    ..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o249.-232.-219.- TMR35-A1FBxxAX1AAA
    Pt100, DIN class A, 4-wire..... mm (40-300/1.57"-11.81"); 6mm (0.25"); w/o196.-182.-172.- TMR35-A11AxxAX1AAA

    Accessories

    Product / VersionPrice / pcs. in USDOrder code
    Configuration kit TXU10- for PC-programmable devices. set-up programme+interface cable for PC with USB-Port. 4 pin plug+ReadWin2000+adapter M12158.44 TXU10-BA
    Cable M12x1 l=5m 5m cable 4x 0.34 mm2, molded PVC angled connector, M12x1 connector screw Cu Sn/Ni, IP67.13.29 51005148

    Prices valid until 31.08.2017 in USD per unit (not including shipping and applicable sales tax). See
    Endress+Hauser Terms and Conditions

  • Application

    Characterized by simplicity and compact construction, the Easytemp TMR35 is available with a range of hygienic process connections. It offers good accuracy and response times and has been specifically designed for hygienic applications with 3-A certification.

    Function

    The compact thermometer consists of a Pt100 class A sensor, (optional) transducer and housing with hygienic process connection. The built-in electronics can be programmed using a PC and TXU10-BA configuration kit to convert the Pt100 input signal into a temperature linear 4 to 20 mA signal.

    Installation instructions

    Hygienic compact thermometer Easytemp TMR35 - INstallation examples

    Pipe installation

     

    a) At angle sections, against the direction of flow

    b) In smaller pipes, turned against the direction of flow

    c) Perpendicular to the direction of flow

     

    L = Insertion length

  • Technical data

    Sensor
    Sensing element 1 × Pt100
    Tolerance Class A according to IEC 751
    Process temperature –50 to +200 °C
    Material 316L
    Surface finishing Ra ≤ 0.8 µm (32 μin)
    Sensor diameter 6 mm (0.24")
    Sensor length 40 to 600 mm (1.6 to 23.6") selectable (please specify)
    Response time T50 = < 1.0 s; T90 = < 2.0 s
    Max. pressure 100 bar / 1500 psi (at 100 mm / 3.94" and 20 °C / 68 °F, depending on process connection)
    Process connection
    Version

    Clamp 1" to 1½" (ISO 2852) or DN 25 to DN 40;

    Clamp 2" (ISO 2852) or DN 50;

    Clamp 2½" (ISO 2852);

    Varivent® F DN25-32, PN40;

    Varivent® N DN40-162, PN40

    Transmitter housing
    Degree of protection IP 66/67
    Electrical connection M12 × 1-plug-in connector
    Material 304
    Output characteristics
    Output signal 4 to 20 mA, 20 to 4 mA / Pt100
    Signal on alarm Sensor break; Sensor short-circuit: ≤ 3.6 mA or ≥ 21.0 mA
    Load Max. (Upower supply –10 V)/0.023 A
    Ind. current requirem. ≤3.5 mA
    Current limitation ≤23 mA
    Switch-on delay 2 s
    Power supply
    Supply voltage Ub = 10 to 35 V DC
    Residual ripple Permitted residual ripple Uss ≤ 3 V at Ub ≥ 13 V, fmax= 1 kHz
    Accuracy
    Transmitter response time 1 s
    Reference operating conditions 0 °C (32 °F) (ice bath)
    Measuring error 0.1 K (0.18 °F) or 0.08 %
    Influence of supply voltage ≤ ±0.01 %/V deviation from 24 V
    Influence of ambient temperature (temperature drift)

    Td = ±(15 ppm / K × (full scale value of measuring range + 200) + 50 ppm/K × set measuring range) × Δθ

    Δθ = deviation of ambient temperature from the reference operating condition

    Long-term stability ≤0.1 K/year or 0.05 %/year
    Influence of load ≤ ±0.02 % / 100 Ω
    Operating conditions
    Ambient temperature -40 to +85 °C (-40 to 185 °F)
    Storage temperature -40 to +85 °C (-40 to 185 °F)
    Climate class As per EN 60 654-1, Class C
    Shock resistance 4 g/2 to 150 Hz as per IEC 60068-2-6
    EMC According to IEC 61326 Series and NAMUR NE21
    Approvals

    3-A

     

    Dimensions (in mm)

    Hygienic compact thermometer Easytemp TMR35 - Dimensions

    a) Clamp

    b) Varivent®

    c) DB (Clamp 1")

    d) DL (Clamp 2")

    e) DL (Clamp 2.5")

    f) LB (Varivent F)

    g) LL (Varivent N)

     

    * Version with extension neck add 35 mm (1.38")

    L = selectable length from 40 to 600 mm (1.6" to 23.6")

     

    Installation according to instruction manual

    Electrical connection

    4 to 20 mA

    Hygienic compact thermometer Easytemp TMR35 - Wiring 1

    1 × Pt100

    Hygienic compact thermometer Easytemp TMR35 - Wiring 2

    a) red

    b) white

    Measuring range

    Code

    Measuring range

    A

    0...+100 °C

    B

    0...+150 °C

    C

    –50...+100 °C

    D

    –50...+150 °C

    E

    –50...+200 °C with extension neck

    F

    0...+200 °C with extension neck

    X

    Freely selectable (Temperature range: –50...+150 °C, please specify)
  • Technical Datasheet

    More documents for TMR35